| General |
| Brand |
Epoch Batteries |
| Model / SKU |
12100-ECO |
| Series |
Eco Series |
| Battery type |
Deep-cycle LiFePO4 battery |
| Battery group size |
BCI Group 24 |
| Chemistry |
LiFePO4 / lithium iron phosphate |
| Cell type |
Prismatic LiFePO4 |
| Cell configuration |
4S1P |
| Bluetooth |
No — use an external battery monitor |
| Self-heating |
No |
| Low-temperature charge protection |
Yes — charging blocked below 0°C / 32°F |
| Cycle life |
4,500+ cycles |
| Warranty |
6-year manufacturer warranty; register within 90 days of purchase for full coverage |
| Voltage and capacity |
| Nominal voltage |
12.8V |
| Nominal capacity |
100Ah @ 0.2C |
| Stored energy |
1.28kWh / 1,280Wh (nominal) |
| Runtime planning energy |
About 1,024Wh (80% of nominal) |
| Estimated runtime |
About 20.5 h at 50W, 10.2 h at 100W, 4.1 h at 250W, 2.0 h at 500W, 1.6 h at 50A (640W) (DC loads at 25°C, new fully charged battery) |
| Operating voltage range |
10.0V – 14.6V |
| Maximum charge voltage |
14.6V |
| Current ratings |
| Max continuous discharge |
100A |
| Peak discharge |
300A for up to 5 seconds |
| Max continuous charge current |
100A, all charging sources combined |
| Recommended charge current |
Up to 50A (0.5C, 50% of capacity) |
| Inverter sizing |
Inverter DC input current within 100A (about 1,280W at 12.8V); usable AC output is lower |
| Deep-cycle load warning |
Do not design continuous loads above the 100A per-battery continuous limit; 300A is a 5-second peak only |
| Series and parallel configuration |
| Series connections |
Max 4 batteries in series (24V, 36V, or 48V system classes) |
| Parallel connections |
Max 16 batteries in parallel |
| Maximum 12V parallel bank |
1,600Ah / 20.48kWh with 16 batteries in parallel |
| Maximum configuration |
4S16P (64 matched batteries): 51.2V nominal, 1,600Ah, 81.92kWh |
| Bank batteries |
Matched 12100-ECO batteries of the same age, condition, and state of charge; fully charge each before connecting it into a bank |
| Temperature |
| Charge temperature range |
0°C to 55°C / 32°F to 131°F |
| Discharge temperature range |
-20°C to 60°C / -4°F to 140°F |
| Recommended storage temperature |
0°C to 35°C / 32°F to 95°F |
| Long-term storage |
About 50% state of charge or higher, loads disconnected; check and recharge at least every 3 months |
| Low-temperature charge protection |
Charging blocked below 0°C / 32°F |
| High-temperature reconnect |
50°C / 122°F |
| Dimensions and weight |
| Length |
10¼ in (260 mm) |
| Width |
6¾ in (171 mm) |
| Height |
9 in (229 mm) |
| Overall dimensions |
10¼ in L × 6¾ in W × 9 in H (260 × 171 × 229 mm) |
| Footprint |
BCI Group 24 |
| Weight |
21 lb / 9.5 kg |
| Mechanical |
| Terminals |
M8 female |
| Terminal torque |
8–12 Nm (71–106 in-lb) |
| Case material |
ABS and PC blend, UL94-V0 flame rating |
| IP rating |
IP54 per IEC 60529 — dust-protected and splash-resistant; not submersible |
| Mounting orientation |
Upright, unless Epoch documentation for this model allows otherwise |
| Recommended charging settings |
| Charger type |
12V LiFePO4-compatible charger, converter, inverter charger, solar controller, or DC-to-DC charger |
| Compatible charger |
Epoch 12V 15A Lithium Battery Charger |
| Maximum continuous charge |
100A, all charging sources combined |
| Recommended charge current |
Up to 50A for one battery; up to 50% of bank capacity for multi-battery banks |
| Bulk / absorption voltage |
14.2V – 14.4V |
| Absorption end condition |
When charge current falls to C/20 (5A) or after 15 minutes, whichever comes first |
| Float voltage |
Disabled preferred, or 13.3V – 13.6V |
| Re-bulk voltage |
13.2V |
| Equalization |
Disabled |
| Temperature compensation |
0mV/°C (disabled) |
| BMS high-voltage cutoff |
14.6V |
| SoC recalibration voltage |
14.6V |
| Charge temperature |
0°C to 55°C / 32°F to 131°F |
| Alternator charging |
DC-to-DC charger programmed for LiFePO4 |
| BMS protection and compliance |
| Smart BMS |
Built in with 20+ safety features |
| Protection functions |
Overcharge, over-discharge, over-current, short-circuit, and high / low temperature disconnects |
| Overcurrent protection |
Install a DC-rated fuse or circuit breaker as close as practical to the battery positive terminal; the BMS is not a substitute |
| Monitoring |
No Bluetooth; use a shunt-based battery monitor for accurate state of charge |
| Cell certification |
UL 1642 (cells) |
| Thermal runaway testing |
UL 9540A (cells) |
| Battery certification |
IEC 62619:2022 |
| Compliance marks |
CE, RoHS |
| Shipping classification |
UN 38.3, Class 9 lithium battery shipping classification |